Detail Bench Conductivity/ TDS/ Resistivity/ Temperatur Meter Model CON 2700

Product Features Featuring auto-standardization, auto-calibration and auto-ranging capabilities, the Eutech CON 2700 accepts 2-cell and 4-cell electrodes, allowing a broad range of measurement at up to ± 1 % full scale accuracy. Meter comes with a multi data screen that shows Conductivity readings, temperature, electrode status, calibration points, date and time all at once. : : Choose auto-calibration with preset values for quick easy calibration, or manual multi-point calibration for greater accuracy : : Easy standardization with auto-standardization feature – detect the exact cell constant value of your electrodes with the press of a button : : Quick, easy electrode diagnosis with the effective cell constants display : : Replatinization in 5 minutes with the built-in replanitization circuit : : Non-volatile memory holds up to 500 data points – time and date-stamped for GLP compliance : : Bi-directional RS232 for easy data transfer to computer : : Cal-due alarm – no more out-dated calibrations! : : Auto-logging function for convenient continuous monitoring : : Limit alarm alerts when reading falls out of range : : Password protection for setup and calibration Specifications Product Specification Description Conductivity Range 0.050 µ S to 500.0 mS Resolution 0.01 / 0.1 µ S ; 0.001 / 0.01 / 0.1 mS Accuracy ± 1 % full scale Cal. Points Up to 5 Cell Constant 0.010 to 10.000 TDS Range ( Depending On TDS Factor) 0.050 ppm to 500 ppt ( @ TDS factor 1.00) Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Accuracy ± 1 % full scale Cal. Points Up to 5 Salinity Range 0.0 to 80.0 ppt Resolution 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Accuracy ± 1 % full scale Resistivity Range 2.000 Ohm to 20.0 MOhm Resolution 0.01 / 0.1 Ohm ; 0.001 / 0.1 kOhm ; 0.01 MOhm Accuracy ± 1 % full scale Temperature Range ( Meter) 0.0 to 100.0 º C / 32.0 to 212.0 º F Resolution 0.1 º C / 0.1 º F Accuracy ± 0.3 º C / ± 0.5 º F Coefficient ( Per º C) Linear & pure ; 0.000 to 10.000 % Normalization 15.0 to 30.0 º C / 59.0 to 86.0 º F Compensation ATC / MTC Power Requirements 9 V DC adapter, 1.3 A ( 100/ 240 VAC, SMPS)
Tampilkan Lebih Banyak