Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Barat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • MMM
  • MMM* INCUCELL, Incubator with natural air convenction, 55 Litre No.Cat: MC000722

MMM* INCUCELL, Incubator with natural air convenction, 55 Litre No.Cat: MC000722

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
75 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail MMM* INCUCELL, Incubator With Natural Air Convenction, 55 Litre No.Cat: MC000722

INCUCELL 55 - Standard Natural, precise – laboratory incubator 55-liter chamber volume Working temperature of from + 5° C above ambient up to 99, 9° C Noiseless operation and fine air flow in the chamber High operation comfort, precise temperature regulation and short times of temperature recovery in the chamber after the door opening High-quality and safe drying, heating and tempering of common laboratory materials in laboratories and industry; suitable for safe processing of microbiological cultures Standard model with a Fuzzy-Logic microprocessor control system; control elements situated on a foil keyboard, process information indicated on a LED display Wide range of optional equipment and accessories Output for a printer or PC connection Validation possibility ( IQ , OQ) Technical data Interior of stainless steel material No. 1.4301 volume 55 l depth 370 mm width 400 mm height 350 mm Tray standard equipment 2 pcs storage area ( w × d) 380× 335 mm racks 4 max. number distance between guide rails 70 mm Maximal weight of the load* ) inside the oven 50 kg/ oven per tray 20 kg/ tray Door 1 pcs External dimensions ( including door and handle) depth 640 mm diameter of the air branch outer / inner 52/ 49 mm width 620 mm height, incl. Feet ( N) and Rolls ( K) 680 ( N) Package dimensions ( three layers carton) depth 730 mm width 700 mm depth 880 mm Weight gross 66 kg nett 55 kg Working temperature ( beginning of the regulation) from 5 ° C above ambient temp. to: 99, 9 ° C Temperature accuracy according to DIN 12 880 T2 at working temperature with closed air flap and door time variation cca ( ± ) < = 0, 2 ° C space deviation cca ( ± ) < 0, 5 ° C Time required to reach 37 ° C with closed air flap and voltage 230 V 49 min Heat emission at 37 ° C 30 W Air exchange speed at 37 ° C 5 per hour Electricity - mains 50/ 60 Hz max. power 0, 3 kW nominal voltage 230 V current 1, 3 A power by stand by 5 W * ) Approx. 50 % of the tray area can be filled in a way a uniform air circulation is enabled inside the chamber. Note: All technical data are related to 22 ° C ambient temperature and + -10 % voltage swing ( if not specified) .
Tampilkan Lebih Banyak